Transmit/Reflect Illumination Switch Knob The illumination control knobs to switch transmit / epi-fluorescent reflect illumination are located on the right side of main body, for easy operation |
Medial Changeable Lens With built-in turret structure, 1x and 1.5x lens can be changed accordingly |
4.3“ LCD Information Touch Screen (A14.1097) In Front of Main Body, For Easy Watch & Control in The Dark Working Condition. --Show Objectives In Use In Nosepiece --Show Cubes In Use In Multi Function Turret --Brightness Memorize & Restore Function --Touch To Adjust Brightness --Touch To Set The System |
Trinocular Head With Built-in Bertrand Lens The built-in bertrand lens can observe the pupil of the objective lens when moving into the light path, and act as a centering telescope
Flexible Transmit Illuminator With retroverted Illuminator, thereby ensuring large space for operation and sample exchange
Long Working Distance Turret Condenser LWD turret structure, with 6 positions for phase contrast annulus, DIC annulus, & bright field view, meets various test needs. condenser N.A.0.55, W.D.26mm |
Camera Adapter At Both Sides & Trinocular Head The optical path output selection dial can distribute the optical images to different ports, providing expansion space for more optical image applications |
◆ Bright Field Observation Unique infinity optical system, combined with semi-apochromatic fluorescent objective lens, effectively eliminates field curvature, chromatic aberration, spherical aberration, coma and other imaging problems, the image is brighter, all magnifications can achieve higher super-resolution and flat type |
◆ Phase Contrast Observation Phase contrast is an optical contrast technology that uses a phase contrast objective lens and a condenser ring. The high-efficiency halogen lamp can provide a bright light source and obtain clear images even at high magnification |
Research Level Inverted Biological Microscope | A14.1096 | A14.1097 | A16.1096 | A16.1097 | A16.1098 | Cata.No. | |
Optical System | NIS60 Infinite Optical System, Semi-APO | ● | ● | ● | ● | ● | |
Observation Method | Bright Field | ● | ● | ● | ● | ● | |
Dark Field | - | - | ○ | ○ | ○ | ||
Phase Contrast | ● | ● | ● | ● | ● | ||
Polarizing | ● | ● | ● | ● | ● | ||
Flourescent | ○ | ○ | ● | ● | ● | ||
DIC | ○ | ○ | ○ | ○ | ○ | ||
LCD Screen | 4.3" LCD Information Touch Screen In Front of Main Body, For Easy Use in Dark Working Condition. --Show Objectives In Use In Nosepiece --Show Cubes In Use In Multi Function Turret --Brightness Memorize & Restore Function --Touch To Adjust Brightness --Touch To Set The System |
- | ● | - | ● | ○ | |
Head | Seidentopf Trinocular Head, Inclined 45°, Interpupillary Distance 47-78mm, Ligth Split Switch E100:P0/E20:P80/E0:P100, With Built-in Bertrand Lens Which Can Be Used As Centering Telescope | ● | ● | ● | ● | ● | |
Eyepiece | SW10x/25mm, High Eyepoint, Diopter Adjustable, Dia.30mm | ○ | ○ | ○ | ○ | ○ | A51.1090-1025 |
SW10x/22mm, High Eyepoint, Diopter Adjustable, Dia.30mm | ● | ● | ● | ● | ● | A51.1090-1022 | |
EW12.5x/17.5mm, High Eyepoint, Diopter Adjustable, Dia.30mm | ○ | ○ | ○ | ○ | ○ | A51.1090-12516 | |
WF15x/16mm, High Eyepoint, Diopter Adjustable, Dia.30mm | ○ | ○ | ○ | ○ | ○ | A51.1090-1516 | |
WF20x/12mm, High Eyepoint, Diopter Adjustable, Dia.30mm | ○ | ○ | ○ | ○ | ○ | A51.1090-2012 | |
Media Lens | Built-in Media Lens Turret 1.0x, 1.5x, Under Nosepiece | ● | ● | ● | ● | - | |
Built-in Media Lens Turret 1.0x, 1.5x. CF, Under Nosepiece | - | - | - | - | ● | ||
Nosepiece | Manual Sextuple Nosepiece, With DIC Slot | ● | - | ● | - | - | |
Coded Manual Sextuple Nosepiece, With DIC Slot | - | ● | - | ● | - | ||
Motorized Coded Manual Sextuple Nosepiece, With DIC Slot, With Objective Protection Function When Switch The Objectives |
- | - | - | - | ● | ||
N-iPLFN PH Infinity Plan Semi-APO Phase Contrast Objective |
4x/0.13, W.D.16.5mm, No Cover Glass | ○ | ○ | ○ | ○ | ○ | A5C.1098-4 |
10x/0.30, W.D.7.4mm, Cover Glass 1.2mm | ● | ● | ● | ● | ● | A5C.1098-10 | |
20x/0.45, W.D.7.5-8.8mm, Cover Glass 0-2mm, With Built-in Correct Ring |
● | ● | ● | ● | ● | A5C.1098-20 | |
40x/0.6, W.D.3-4.4mm, Cover Glass 0-2mm, With Built-in Correct Ring |
● | ● | ● | ● | ● | A5C.1098-40 | |
60x/0.75, W.D.1.8-2.6mm, Cover Glass 0.1-1.3mm, With Built-in Correct Ring |
○ | ○ | ○ | ○ | ○ | A5C.1098-60 | |
Focusing | Coaxial Coarse & Fine Focusing, Focusing Range 9mm (Up 7mm, Down 2mm), Coarse Stroke 2mm, Fine Stroke 0.2mm | ● | ● | ● | ● | - | |
Motorized Z Axies (Optical Grating Type) Focusing System, Focusing Range 9mm (Up 7mm, Down 2mm), Focusing Resloution 0.02um With Optical Grating, Movement Repeat Positioning Accuracy +/-0.1um, Prevent Stage Fall Down Function | - | - | - | - | ● | ||
Working Stage | Three Layer Mechnical Stage, Moving Range 130x85mm, Flexible Knob, Available For Different Size Small Stage Mounted on Top Layer | ● | ● | ● | ● | - | A54.1098 |
Motorized X/Y Axies (Optical Grating Type) Mechnical Stage, Size 325x144mm, Moving Range 130x100mm, Max Speed 10mm/s, Resloution 0.1um, Repeat Accuracy +/-0.5um, Available For Different Size Small Stage Mounted on Top Layer, With Separate Communication/Main Control Box & Stick |
- | - | - | - | ● | A54.1098-M | |
Dia.38mm Holder For Slide & Petri Dish | ● | ● | ● | ● | ● | A54.1098-38 | |
Dia.54mm Holder For Petri Dish | ● | ● | ● | ● | ● | A54.1098-54 | |
96 Holes Plate Holder | ● | ● | ● | ● | ● | A54.1098-96 | |
Terasaki Holder | ● | ● | ● | ● | ● | A54.1098-TH | |
Universal Holder | ● | ● | ● | ● | ● | A54.1098-UH | |
Condenser | Long Working Distance Turret Condenser, N.A.0.55, W.D.26mm, With 6 Positions For Phase Contrast Annulus, DIC Annulus, And Bright Field View |
● | ● | ● | ● | - | A56.1098 |
Motorized Long Working Distance Turret Condenser, N.A.0.55, W.D.26mm, With 6 Positions For Phase Contrast Annulus, DIC Annulus, And Bright Field View | - | - | - | - | ● | A56.1098-M | |
Multi Function Turret | Multi Function Turret Under Nosepiece, With 6 Positions For Cubes Of Bright Field, Dark Field, Phase Contrast, Polarizing, Fluorescent View, Turning The Disc To Easily Switch Observation Methods | ● | ● | ● | - | - | |
Coded Multi Function Turret Under Nosepiece, With 6 Positions For Cubes Of Bright Field, Dark Field, Phase Contrast, Polarizing, Fluorescent View, Turning The Disc To Easily Switch Observation Methods | - | - | - | ● | - | ||
Motorized Coded Multi Function Turret Under Nosepiece, With 6 Positions For Cubes Of Bright Field, Dark Field, Phase Contrast, Polarizing, Fluorescent View, Turning The Disc To Easily Switch Observation Methods | - | - | - | - | ● | ||
Dark Field | Dark Field Block, Put In Multi Function Turret, For Reflect Light Source | ○ | ○ | ○ | ○ | ○ | A5D.1098 |
Polarizing For Transmit Light | Polarizer Filter On LWD Turret Condenser | ● | ● | ● | ● | ● | A5P.1098-P |
Analyzer Slide, Insert Into Slot On Nosepiece, 360° Rotatable | ● | ● | ● | ● | ● | A5P.1098-A | |
Polarizing For Reflect Light | Polarizer Light Block, Put In Multi Function Turret | ○ | ○ | ○ | ○ | ○ | A5P.1098-PL |
Circularly Polarized Light Block, Put In Multi Function Turret | ○ | ○ | ○ | ○ | ○ | A5P.1098-CP | |
Phase Contrast | Phase Contrast Annulus 10x/20x, Put In Turret Condenser | ● | ● | ● | ● | ● | A5C.1096-1020 |
Phase Contrast Annulus 40x, Put In Turret Condenser | ● | ● | ● | ● | ● | A5C.1096-40 | |
Phase Contrast Annulus 60x, Put In Turret Condenser | ○ | ○ | ○ | ○ | ○ | A5C.1096-60 | |
DIC | DIC Annulus 10x, Put In LWD Turret Condenser | ○ | ○ | ○ | ○ | ○ | A5C.1097-A10 |
DIC Annulus 20x, Put In LWD Turret Condenser | ○ | ○ | ○ | ○ | ○ | A5C.1097-A20 | |
DIC Annulus 40x, Put In LWD Turret Condenser | ○ | ○ | ○ | ○ | ○ | A5C.1097-A40 | |
DIC Annulus 60x, Put In LWD Turret Condenser | ○ | ○ | ○ | ○ | ○ | A5C.1097-A60 | |
DIC Slider 10x, Insert Into Slot On Nosepiece | ○ | ○ | ○ | ○ | ○ | A5C.1097-S10 | |
DIC Slider 20x, Insert Into Slot On Nosepiece | ○ | ○ | ○ | ○ | ○ | A5C.1097-S20 | |
DIC Slider 40x, Insert Into Slot On Nosepiece | ○ | ○ | ○ | ○ | ○ | A5C.1097-S40 | |
DIC Slider 60x, Insert Into Slot On Nosepiece | ○ | ○ | ○ | ○ | ○ | A5C.1097-S60 | |
Illumniation | Transmit/Reflect Illumnation Switch Knob, On Right Side Of Main Body, Press To Switch Transmit And Reflect Switch Light Quickly | ● | ● | ● | ● | ● | |
Transmit Light Source |
12V100W Halogen Kohler Illumination, Brightness Adjustable, Flexible Illuminator Body Can Retrovert From Optical Path For Large Space of Operation And Sample Exchange |
● | ● | ● | ● | ● | A56.1095-12V100W |
10W S-LED Kohler Illumination, Brightness Adjustable | ○ | ○ | ○ | ○ | ○ | A56.1095-10WLED | |
Reflect Light Source |
Large Filter Holder Slide With 3 Holes | ○ | ○ | ● | ● | ● | A56.1095-LS |
Field Diaphram Slide, Center Adjustable, | ○ | ○ | ● | ● | ● | A56.1095-FS | |
Small Empty Slide | ○ | ○ | ● | ● | ● | A56.1095-ES | |
Aperture Diaphragm Slide | ○ | ○ | ● | ● | ● | A56.1095-AS | |
Neutral Filter | ○ | ○ | ● | ● | ● | A56.1095-NE | |
Reflect Fluorescent Light Source | Reflect 100W Osram Mercury HBO Fluorescent Light House Intelligent Power Supply Control Box With Barrier To Stop/Recover Fluorescent Illumination Quickly |
○ | ○ | ● | ● | ● | A5F.1095-100W |
10W S-LED Fluorescent Light, 4 Color Bands, Brightness Adjustable By Control Box | ○ | ○ | ○ | ○ | ○ | A5F.1095-10WLED | |
75W Metal Halide Light Source, Life Time 2000 Hours | ○ | ○ | ○ | ○ | ○ | A5F.1095-75WM | |
Fluorescent Filter B Block, Put In Multi Function Turret | ○ | ○ | ● | ● | ● | A5F.1095-B | |
Fluorescent Filter G Block, Put In Multi Function Turret | ○ | ○ | ● | ● | ● | A5F.1095-G | |
Fluorescent Filter U Block, Put In Multi Function Turret | ○ | ○ | ● | ● | ● | A5F.1095-U | |
Fluorescent Filter V Block, Put In Multi Function Turret | ○ | ○ | ○ | ○ | ○ | A5F.1095-V | |
Metallurgical | Upgrade To A13.1090 Inverted Metallurgical Microscope | ○ | ○ | ○ | ○ | ○ | A13.1090 |
Adapter | 3 Camera Ports, On Both Side Of Main Body And Head, Turret Switch Between: --Trinocular Port Switch E100:P0/E20:P80/E0:P100 --Left Port C-Mount 1.0x E0:P100 --Right Port C-Mount 1.0x E20:P80 |
● | ● | ● | ● | ● | |
C-Mount 0.4x | ○ | ○ | ○ | ○ | ○ | A55.1095-04 | |
C-Mount 0.5x | ○ | ○ | ○ | ○ | ○ | A55.1095-05 | |
C-Mount 1.0x | ● | ● | ● | ● | ● | A55.1095-10 | |
Software | NOMIS Basic Image Processiing Software | ○ | ○ | ○ | ○ | ○ | A30.1090 |
Note:"●"In Table Is Standard Outfits,"○" Is Optional Accessories "-" Is Unavailable |